Introduction
Reusable High-Performance Disinfectant
This disinfectant is specifically designed for high-level disinfection or sterilization of endoscopes and their accessories. It is suitable for manual disinfection procedures or automatic endoscope cleaning and disinfection machines, meeting the strict infection control requirements of healthcare institutions.
Features / strengths
Product Information and Specifications
Product Name:
Endocide High-Level Disinfectant and Sterilant
Bottle A Capacity: 300 mL
Bottle B Capacity: 4700 mL
Packaging per Box: 2 bottles of A liquid + 2 bottles of B liquid
Product Name:
Endocide High-Level Disinfectant and Sterilant Test Strips
Quantity: 100 strips per bottle
Packaging per Box: 1 bottle
Usage Instructions
Mixing: No dilution is required for A liquid and B liquid. Simply mix them before use for quick and easy operation.
Preparation: Pour A liquid (green label) into B liquid (blue label) and mix thoroughly.
Efficacy: Endocide has been experimentally validated to effectively eliminate bacteria, mycobacteria, viruses, fungi, and bacterial spores, meeting high-level disinfection and sterilization requirements.
Test Strip Usage:
Contact the test strip for 3 seconds and read the results within 15 seconds. If the color shows brown/black, it indicates that the peracetic acid concentration is above 1000 ppm, which is within the effective range.
Key Ingredients
Peracetic Acid (PAA): 0.24%
Hydrogen Peroxide: 1.56%
Product Features and Safety
No Quaternary Ammonium Compounds: Free from staining issues.
Versatile Use: Suitable for manual or automatic disinfection of various medical devices.
Compatibility: Highly compatible with materials used in Olympus and Fujinon endoscopes, as well as most reusable medical instruments.
Corrosion Protection: Contains corrosion inhibitors, surfactants, and buffers to effectively protect instruments from corrosion.
Storage Instructions
Storage: Keep in the original packaging and store in a cool place, avoiding direct sunlight.
Shelf Life:
Unopened: 18 months
Opened: 4 months
Usage Duration and Recommended Operating Times
Reusability: Mixed A liquid and B liquid can be reused for up to 14 days.
High-Level Disinfection Time: 5 minutes
Sterilization Time: 10 minutes
Concentration and Testing
Initial Peracetic Acid Concentration: 2000–2700 ppm
Minimum Effective Concentration (MEC): 1000 ppm
Note: It is recommended to use Endocide test strips before each use to confirm that the concentration remains above the effective range.
Specification in detail
Specification
Disinfectant (Bottle A: 300 mL / Bottle B: 4700 mL), Test Strips (100 strips per bottle)