Introduction
The GalliaPharm® 68Ge/68Ga Radionuclide Generator from Eckert & Ziegler Radiopharma GmbH is a pharmaceutical product for obtaining the positron emitter 68Gallium, independent of a cyclotron.
GalliaPharm® is a closed system consisting of pharmacopoeia grade borosilicate glass column containing a titanium dioxide bed on which 68Ge is adsorbed. 68Ga is continuously produced by decay of its radioactive parent 68Ge and is eluted with sterile ultrapure 0,1 mol/l hydrochloric acid. GalliaPharm® is available with the following activities: 0,74 GBq, 1,11 GBq, 1,48 GBq and 1,85 GBq (20 mCi, 30 mCi, 40 mCi, 50 mCi).
Features / strengths
The GalliaPharm® is produced under GMP conditions ensuring highest quality standards and is designed to minimize both 68Ge breakthrough and metal impurities. No metals are used within the closed system. All components are compliant with the monographs of the European Pharmacopeia (if available) or their suitability for the respective application has been tested otherwise.
Specification in detail
Dimensions (W x D x H)
132 x 133 x 230 mm
Number of possible elutions
> 700 elutions
Available activities
0,74 GBq, 1,11 GBq, 1,48 GBq, 1,85 GBq (20 mCi, 30 mCi, 40 mCi, 50 mCi)

Information
Introduction
The GalliaPharm® 68Ge/68Ga Radionuclide Generator from Eckert & Ziegler Radiopharma GmbH is a pharmaceutical product for obtaining the positron emitter 68Gallium, independent of a cyclotron.
GalliaPharm® is a closed system consisting of pharmacopoeia grade borosilicate glass column containing a titanium dioxide bed on which 68Ge is adsorbed. 68Ga is continuously produced by decay of its radioactive parent 68Ge and is eluted with sterile ultrapure 0,1 mol/l hydrochloric acid. GalliaPharm® is available with the following activities: 0,74 GBq, 1,11 GBq, 1,48 GBq and 1,85 GBq (20 mCi, 30 mCi, 40 mCi, 50 mCi).
Features / strengths
The GalliaPharm® is produced under GMP conditions ensuring highest quality standards and is designed to minimize both 68Ge breakthrough and metal impurities. No metals are used within the closed system. All components are compliant with the monographs of the European Pharmacopeia (if available) or their suitability for the respective application has been tested otherwise.
Specification in detail
Dimensions (W x D x H)
132 x 133 x 230 mm
Number of possible elutions
> 700 elutions
Available activities
0,74 GBq, 1,11 GBq, 1,48 GBq, 1,85 GBq (20 mCi, 30 mCi, 40 mCi, 50 mCi)